Application:
The cable is used to transmit and distribute power on the power line of rated of AC voltage 0.6/1KV or lower
Type and Specification
TypeNameApplication
NH-YJVNH-YJLVPower cable with XLPE insulation and PVC sheathLaying indoors and outdoors,able to withstant some laying traction,unable to withstand external pressure and mechanical forces,single core is not allowable to lay up in magnetic pipelines
ZCN-YJVZCN-YJLVPower cable with XLPE insulation , PVC sheath and flame retardant category C
WDZCN-YJYWDZCN-YJLYPower cable with XLPE insulation , polyolefin sheath and low smoke halogen free flame retardant category C
NH-YJV22NH-YJLV22Power cable with XLPE insulation steel tape armoring,PVC sheathLaying underground directly,able to withstand external mechaniical forces,but unable to withstand large pulling forces
ZCN-YJV22ZCN-YJLV22Power cable with XLPE insulation steel tape armoring,PVC sheath and flame retardant category C
WDZCN-YJY23WDZCN-YJLY23Power cable with XLPE insulation steel tape armoring,polyolefin sheath and low smoke halogen free flame retardant category C
NH-YJV32NH-YJLV32Power cable with XLPE insulation steel wire armoring,PVC sheathLaying in the water or high drop area,able to withstand external mechanical forces and quite pulling forces
ZCN-YJV32ZCN-YJLV32Power cable with XLPE insulation steel wire armoring,PVC sheath and flame retardant category C
WDZCN-YJY33WDZCN-YJLY33Power cable with XLPE insulation and PVC sheath
NH-YJV42NH-YJLV42Power cable with XLPE insulation ,heavy steel wire armoring ,PVC sheath
ZCN-YJV42ZCN-YJLV42Power cable with XLPE insulation ,heavy steel wire armoring ,PE sheath,free flame retardant category C
WDZCN-YJY43WDZCN-YJLY43Power cable with XLPE insulation ,heavy steel wire armoring ,polyolefin sheath and low smoke halogen free flame retardant category C
Working condition
1The rated voltage of cable is 0.6/1kv
2Max.rated temperature fo cable conductor is90
3During short circuit ( the longest lasting time is shall be not more than 5S),Max. temperature of cable conductor is not more than 250
4When installation, the ambient temperature should not be lower than 0, its minimum bending radius should not be less than 12 times of outer diameter of cable.